Skip to content
Nirvana NE Series pool heat pump, dark grey cabinet and side fan
NE45 brochure, page 1
NE45 brochure, page 2
NE55 to NE100 brochure, page 1
NE55 to NE100 brochure, page 2
1 / 5

Pool heat pumpNirvana NE Series

375+ Google reviews of Piscines VP

Nirvana's most popular heat pump: compact, efficient and designed in Quebec. Piscines VP chooses the right capacity with you, installs it and takes care of its opening and closing every season.

Choose the model
BTU—
COP—
Breaker—
Noise at 10 m—
Free quote, no obligationClear price, no surprises
1We call you back
2You get a clear price
3You decide, no pressure
Installed by our techniciansFixed date and timeFinancing available
4 models44,000 to 98,000 BTU
COP 5.9–6.0AHRI certified
5 yearsParts and labour

At a glance

The Nirvana NE Series is a 240 V pool heat pump available in four capacities, from 44,000 to 98,000 BTU. It has a titanium heat exchanger, active hot-gas defrost and AHRI-certified performance. Since 2026, Nirvana names its models NE50, NE60, NE80 and NE100 (formerly NE45, NE55, NE75 and NE100). Piscines VP installs it in Laval, on the North Shore and in the Lower Laurentians.

  • Double-twist titanium heat exchanger
  • Active hot-gas defrost
  • 41 to 44 dB at 10 m
  • 5-year parts and labour warranty
Is it the right choice for you?

Who the NE Series is for

We'd rather steer you to the right equipment from the start. Here's when we recommend it, and when we suggest something else.

We recommend it if

  • You want a reliable heat pump with the best value in the Nirvana lineup.
  • Your pool is an above-ground up to 27 ft or an inground up to 18 × 32.
  • You have a 240 V electrical supply near the pool, or you can have one installed.
  • You want a quiet unit: 41 to 44 dB at 10 m.

Another choice if

  • You only have 120 V: Nirvana NE 20.
  • You want a cabinet with a 15-year warranty: Nirvana FC.
  • You're aiming for the highest efficiency: Nirvana PV / PVT.
  • Your pool is larger than 18 × 32: FC or PV, which are more powerful.
Construction

What's inside

Titanium

Double-twist exchanger

Titanium resists chlorine and salt. The double twist increases the exchange surface.

Hot gas

Active defrost

The unit melts the frost on the evaporator by itself and keeps heating when nights are cool.

44 dB

Quiet

From 41 to 44 dB at 10 m depending on the model, according to Nirvana's 2026 brochure.

AHRI

Certified performance

Published capacities and COPs are verified to the AHRI 1160 standard.

Spec sheet

NE Series specifications

Four capacities, all 240 V. Tap a model to highlight it.

ModelFormer nameBTU 80/80/80COP 80/80/80BTU 50/63/80COP 50/63/80BreakerAmperageNoise at 10 mWeightTypical pool
NE50NE4544 0005,925 5003,820 A9,6 A41 dB124 lb18 ft · 10 × 20
NE60NE5555 0006,035 0004,020–30 A14 A42 dB135 lb21 ft · 15 × 30
NE80NE7573 5005,946 5004,030 A18,5 A43 dB190 lb24 ft · 16 × 32
NE100NE10098 0006,062 0004,140 A21 A44 dB256 lb27 ft · 18 × 32
Power supply: 240 VScroll compressor, R410A refrigerantABS cabinet on a metal frameTypical pool: above-ground · inground, per Nirvana (June to August)
5years
parts
5years
labour
Tool

Which model for my pool?

Choose your pool and your season: we'll estimate the capacity you need. A technician always confirms before the quote.

Pool type
Size
Your swimming season
Our suggestion
—

My priceAn approximation, not an exact science. Volume estimated using an average depth of 1.2 m for above-ground pools and 1.5 m for inground pools, then 1.3 BTU/L (June to August) or 1.5 BTU/L (May to September). Wind, shade and a solar cover change the need: a technician always confirms.
What VP does on top

Bought, installed and maintained by the same team

A heat pump is only as good as its installation. With us, you know who is coming, when they're coming, and what was done.

1

Assessment

Pool dimensions, location and electrical panel. Often doable with a few photos.

2

Installed price

A clear quote: unit and Standard or Premium installation package, no surprises.

3

Installation

By our technicians, on a fixed date and time, confirmed in advance.

4

Start-up

We start up the unit with you and show you the settings.

5

Every season

Opening and closing by the same team, with an email of what was done after every visit.

It's the heat pump we install the most: reliable, quiet and easy to maintain.

A word from the VP expert
Compare

Compare our heat pumps

Need help choosing? Read our guides Which heat pump for my pool and Inverter or classic.

ModelCabinetPowerPowerKey strength
Nirvana NEComposite on a metal frame240 V44,000 to 98,000 BTUThe best value in the Nirvana line
Nirvana FCFibreglass-reinforced composite240 V56,000 to 145,000 BTUDurability, 15-year cabinet warrantySee →
Nirvana PV / PVTFibreglass-reinforced composite240 V77,000 to 175,000 BTU2-stage compressor, COP up to 10.6See →
Nirvana NE 20Composite120 V (plug-in)19,800 BTUSmall above-ground pools, no electricianSee →
HeliosMetal240 V50,000 and 120,000 BTUEntry-level price, made in CanadaSee →
Frequently asked questions

Your questions about the Nirvana NE

Which Nirvana NE for my pool?

Our rule of thumb: about 1.3 BTU per litre of water to swim from June to August, and 1.5 BTU per litre from May to September. It's an approximation, not an exact science: wind, shade and a solar cover change the need. Example: a 24 ft above-ground holds about 51,000 L, or about 67,000 BTU from June to August: an NE80. A 16 × 32 inground (about 71,000 L) needs about 93,000 BTU: an NE100. A technician always confirms before the quote.

Why did the names change (NE45, NE55, NE75)?

Nirvana renamed the series in 2026: NE45 becomes NE50, NE55 becomes NE60 and NE75 becomes NE80. The published capacities stay the same.

Is the Nirvana NE an Inverter heat pump?

No. It uses a conventional scroll compressor. We recommend this type of unit for its reliability in our climate.

What do 80/80/80 and 50/63/80 mean?

They are the performance test conditions: air temperature, humidity and water temperature in °F. 80/80/80 is a hot summer day. 50/63/80 is closer to a cool evening in May or September: that's the value to look at to extend your season.

What's included in the installation?

Two packages. Standard: delivery, 10 feet of piping, the necessary fittings and their installation, with warranty. Premium: the entire Standard package, plus a bypass to control the water flow to the heat pump, which reduces wear caused by pressure. The electrical hookup is not included: it must be done by an electrician.

How much does an installed Nirvana NE cost?

The price depends on the model and the installation package (Standard or Premium). The electrical hookup is done by an electrician and is not included. We send you a clear price after the assessment. Financing is available.

What does the warranty cover?

5 years on parts and 5 years on labour, under Nirvana's terms.

Does the heat pump need to be closed for the winter?

Yes. It must be drained and protected in the fall. We take care of it during the pool closing. See also: how to close a heat pump.

Do you install in my city?

Yes, if you're in Laval, Terrebonne, Blainville, Mirabel, Saint-Jérôme or elsewhere on the North Shore and in the Lower Laurentians. See all the cities we serve.

Ready to book your day?

No account, in 2 minutes. No need to be home.